Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21.189
Filter
1.
BMC Musculoskelet Disord ; 25(1): 373, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38730376

ABSTRACT

INTRODUCTION: An acute Achilles tendon rupture represents a common tendon injury, and its operative methods have been developed over the years. This study aimed to quantify the learning curve for the minimally invasive acute Achilles tendon rupture repair. METHODS: From May 2020 to June 2022, sixty-seven patient cases who received minimally invasive tendon repair were reviewed. Baseline data and operative details were collected. The cumulative summation (CUSUM) control chart was used for the learning curve analyses. Achilles tendon rupture score (ATRS), American Orthopedic Foot and Ankle Society (AOFAS) ankle/hindfoot score, and visual analog scale (VAS) at 3/6/9/12 months were calculated to assess the clinical outcomes. RESULTS: Thirty-six cases underwent at least a year of follow up and were enrolled in this study. The gender ratio and average age were 80.5% and 32.5 years. The linear equation fitted well (R2 = 0.95), and CUSUM for operative time peaked in the 12th case, which was divided into the learning phase (n = 12) and master phase (n = 24). No significant difference was detected between the two groups in clinical variables, except for the operative time (71.1 ± 13.2 min vs 45.8 ± 7.2 min, p = 0.004). Moreover, we detected one case with a suture reaction and treated it properly. CONCLUSION: Minimally invasive Achilles repair provides an opportunity for early rehabilitation. Notably, the learning curve showed that the "lumbar puncture needle and oval forceps" technique was accessible to surgeons.


Subject(s)
Achilles Tendon , Learning Curve , Minimally Invasive Surgical Procedures , Tendon Injuries , Humans , Achilles Tendon/surgery , Achilles Tendon/injuries , Male , Female , Adult , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/education , Minimally Invasive Surgical Procedures/instrumentation , Middle Aged , Tendon Injuries/surgery , Rupture/surgery , Retrospective Studies , Treatment Outcome , Surgical Instruments , Needles , Operative Time
2.
Folia Med (Plovdiv) ; 66(2): 235-242, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38690819

ABSTRACT

INTRODUCTION: Tooth extraction is still one of the most common dental procedures, routinely performed for a variety of reasons. Tooth extraction forceps and elevators are well-known extraction instruments which have been the standard in tooth extraction procedures for well over a hundred years. Physics forceps are one possible alternative, aiming to perform less traumatic and more predictable extractions.


Subject(s)
Surgical Instruments , Tooth Extraction , Humans , Tooth Extraction/instrumentation , Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Female , Male , Adult , Middle Aged , Young Adult , Aged
4.
Prog Brain Res ; 285: 115-126, 2024.
Article in English | MEDLINE | ID: mdl-38705711

ABSTRACT

The only instruments for opening the cranium considered in this chapter are drills, and in some cases facilitated with a special chisel called a lenticular. There were two kinds of trepan. The modiolus was the Latin name for a crown trepan which had a circular base with teeth which sawed a hole. Then there were the non-penetrating trepans which had a bit shaped to prevent unwanted penetration. They made small openings which could be joined by chisels to remove altogether larger areas of bone than were accessible to modioli. They were the favored instrument from the ancient world up to the Renaissance. At the beginning of the Renaissance, there was a move toward greater use of crown trepans and various methods were applied to stop them sinking too far inward. These included wings in the outer wall and changing the shape of the bit from cylindrical to conic. In time preferences returned to the cylindrical shape and larger diameters. There was also two instruments called lenticulars, the illustrations of which have been confused in the literature. It is now clear that the Roman instrument was shaped to cut the cranium and minimize the need for trepanation. The Renaissance instrument had a different shape and was used to smooth rough bone edges and excise spicules penetrating the meninges. They were simply two different instruments to which the same name was applied.


Subject(s)
Surgical Instruments , Surgical Instruments/history , History, Ancient , Humans , History, Medieval , History, 16th Century , History, 15th Century , Skull/anatomy & histology , Trephining/history , Trephining/instrumentation
5.
PLoS One ; 19(5): e0302737, 2024.
Article in English | MEDLINE | ID: mdl-38696516

ABSTRACT

BACKGROUND: As advancements in surgical instruments and techniques continue to evolve, minimally invasive surgery has become increasingly preferred as a means of reducing patient pain and recovery time. However, one major challenge in performing minimally invasive surgery for early gastrointestinal cancer is accurately identifying the location of the lesion. This is particularly difficult when the lesion is confined to the lumen of the intestine and cannot be visually confirmed from the outside during surgery. In such cases, surgeons must rely on CT or endoscopic imaging to locate the lesion. However, if the lesion is difficult to identify with these images or if the surgeon has less experience, it can be challenging to determine its precise location. This can result in an excessive resection margin, deviating from the goal of minimally invasive surgery. To address this challenge, researchers have been studying the development of a marker for identifying the lesion using a radio-frequency identification (RFID) system. One proposed method for clinical application of this detection system is to attach an RFID tag to an endoscopic hemostatic clip and fix it to the intended position, providing a stable marker for the inner wall of the organ. This approach has the potential to improve the accuracy and effectiveness of minimally invasive surgery for early gastrointestinal cancer. METHODS: In the development of a marker for identifying gastrointestinal lesions using a radio-frequency identification (RFID) system, the shape of the clip and suitable materials for attaching the RFID tag were determined through finite element method (FEM) analysis. A prototype of the clip was then fabricated and ex-vivo experiments were conducted using porcine intestine to evaluate the stability of the clip in relation to its position. To further evaluate the performance of the RFID-integrated clip in vivo, the clip was placed in the gastric wall of the stomach of anesthetized porcine using an endoscopic instrument. The clip was then detected using a RFID detector designed for laparoscopic approach. And later, the accuracy of detection was confirmed by incising the lesion. RESULTS: The design and fabrication of a clip with varying thicknesses using STS316 and STS304 stainless steel were accomplished using the results of finite element method analysis. The stability of the clip was evaluated through ex-vivo experiments, showing it to be a viable option. In-vivo experiments were performed on anesthetized porcine, in which the RFID-integrated clip was placed in the gastric wall and detected using a custom-made RFID detector. The resection margin, measured at about 30 mm from the detector position, was accomplished with low error. These findings indicate the feasibility and efficacy of using an RFID-integrated clip as a marker in minimally invasive surgery for the identification of gastrointestinal lesions. CONCLUSIONS: The study evaluated the feasibility of using stainless steel clips for lesion detection in endoscopic surgery using computer-aided engineering analysis and ex-vivo experimentation. Results showed that STS304 was suitable for use while STS316L was not. The ex-vivo experiments revealed that the clip holding force and tissue retention length varied depending on the location of attachment. In-vivo experiments confirmed the accuracy and usefulness of the RFID lesion detection system. However, challenges remain for its use in clinical field, such as ensuring the stability of the clip and the safe attachment of the RFID tag, which requires further research for commercialization.


Subject(s)
Laparoscopy , Surgical Instruments , Laparoscopy/methods , Laparoscopy/instrumentation , Animals , Swine , Radio Frequency Identification Device/methods , Humans
6.
Prog Brain Res ; 285: 157-178, 2024.
Article in English | MEDLINE | ID: mdl-38705715

ABSTRACT

The chapter begins with also an outline of the characteristics of four surgeons who changed the direction of thinking and hence of practice. This is followed by a review of the changing ideas which governed surgical practice. Chapter "Two surgical instruments" by Jeremy C. Ganz has examined the uses of drills and lenticulars. In this chapter there is an appraisal of the other instruments used during cranial surgery and how their use related to changing ideas. Finally, there is a concluding section which ties all these elements together.


Subject(s)
Surgical Instruments , Humans , History, 20th Century , History, 19th Century , Neurosurgery , Neurosurgical Procedures
7.
Neurosciences (Riyadh) ; 29(2): 90-95, 2024 May.
Article in English | MEDLINE | ID: mdl-38740406

ABSTRACT

OBJECTIVES: To investigate the factors that contribute to the development of cerebral edema after aneurysm clipping in individuals with aneurysmal subarachnoid hemorrhage (aSAH). METHODS: A total of 232 patients with aSAH caused by rupture and treated with aneurysm clipping were included in the retrospective analysis of clinical data. Postoperatively, the participants were categorized into two groups based on the presence or absence of cerebral edema: a complication group (n=33) and a non-complication group (n=199).A comparison was made between the overall data of the 2 groups. RESULTS: In the complication group, there were higher proportions of patients experiencing recurrent bleeding, aneurysm in the posterior circulation, Fisher grade III-IV, World Federation of Neurosurgical Societies (WFNS) grade II, Hunt-Hess grade III-IV, concomitant hypertension, duration from onset to operation ≥12 h, and concomitant hematoma compared to the non-complication group (p<0.05). Cerebral edema after aneurysm clipping was associated with several risk factors including repeated bleeding, aneurysm in the back of the brain, Fisher grade III-IV, WFNS grade II, Hunt-Hess grade III-IV, simultaneous high blood pressure and hematoma, and a duration of at least 12 hours from the start of symptoms to the surgical procedure (p<0.05). CONCLUSION: In patients with aSAH, the risk of cerebral edema after aneurysm clipping is increased by recurrent bleeding, aneurysm in the posterior circulation, Fisher grade III-IV, WFNS grade II, Hunt-Hess grade III-IV, concomitant hypertension and hematoma, and duration of ≥12 h from onset to operation.


Subject(s)
Brain Edema , Subarachnoid Hemorrhage , Humans , Subarachnoid Hemorrhage/surgery , Subarachnoid Hemorrhage/complications , Male , Female , Middle Aged , Brain Edema/etiology , Risk Factors , Retrospective Studies , Adult , Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Intracranial Aneurysm/surgery , Intracranial Aneurysm/complications , Neurosurgical Procedures/adverse effects , Surgical Instruments/adverse effects , Aneurysm, Ruptured/surgery , Aneurysm, Ruptured/complications
10.
J Evid Based Integr Med ; 29: 2515690X241244845, 2024.
Article in English | MEDLINE | ID: mdl-38613379

ABSTRACT

Garcinia dulcis (GD) extract possesses anti-hypertensive property that are poorly characterized. This study aimed to investigate an anti-inflammatory effect of GD flower extract in the 2-kidney-1-clip (2K1C) hypertensive compared to sham operative (SO) rat. Male Wistar rats were divided into 2 groups; the 2K1C group in which a silver clip was placed around renal artery to induce hypertension, and the SO normotensive group. Four weeks later, each group of rats were further divided into 2 subgroups, each subgroup was orally gavaged of either corn oil (vehicle) or 50 mg/kg BW GD extract daily for 4 weeks. The malondialdehyde (MDA) levels in serum, liver, and kidney were determined. Hematoxylin and eosin staining was carried out for histological examination, Periodic acid - Schiff staining for glomerular injury, Masson's trichrome staining for renal fibrosis, and immunohistochemistry for either tumor necrosis factor alpha (TNF-α) or endothelial nitric oxide synthase (eNOS) investigation. Taken together, our results demonstrated that GD flower extract decreased the MDA level in both serum and liver and kidney tissue and suppressed the expression of TNF-α in both liver and kidney of 2K1C hypertensive rats. Mesangial cell proliferation, expansion of mesangial matrix, widening Bowman's capsule space, congestion of glomerular capillary and vessel, cloudy swelling of renal tubular epithelial cell, and renal fibrosis were observed in the kidneys of 2K1C rats. Therefore, we concluded that GD flower extract can alleviate liver and kidney inflammation in which partially attenuates the glomerular injury in the 2K1C rat.


Subject(s)
Hypertension , Tumor Necrosis Factor-alpha , Male , Rats , Animals , Tumor Necrosis Factor-alpha/genetics , Rats, Wistar , Kidney , Liver , Inflammation/drug therapy , Surgical Instruments , Fibrosis , Plant Extracts/pharmacology
11.
PLoS One ; 19(4): e0301590, 2024.
Article in English | MEDLINE | ID: mdl-38598515

ABSTRACT

To promote the comprehensive utilization of corn stover and the development of field water-saving irrigation technology, a method of returning corn stover to the field was prosed; in this method, the crop stalks were crushed, mixed with soil in different proportions of adulteration, and then extruded to form hollow round tubes. To compare the influence of the winch blade with or without a diameter change on the composite pipe molding performance, two composite pipe molding devices were theoretically designed, simulated, and analyzed using discrete element simulation software, and a composite pipe molding bench test was performed. The simulation test revealed that the composite pipe molding rate of the winch blade without the reducer molding device was 3.45 kg/s, the output power of the winch shaft was 20.7 kW, the composite pipe molding rate of the winch blade with the reducer molding device was 1.20 kg/s, and the output power of the winch shaft was 18.75 kW. By calculating the weighted average of two indices, the composite pipe forming rate and the winch shaft output power, the comprehensive performance index of the composite pipe forming device without a reducer was greater than that of the device with a reducer. The composite pipe forming bench test revealed two kinds of molding devices with an extrusion molding with an outer diameter of 100 mm and an inner diameter of 30 mm. The composite pipe density test average was greater than 1.30 g/cm3 and met the requirements of composite pipe molding; the winch blade without a reducer molding device had an average composite pipe molding rate of 3.23 kg/s, and the winch blade with an average reducer molding rate of 2.07 kg/s. The forming rate of the composite pipe without a reducer was faster. Therefore, a winch blade without a reducer composite pipe molding device is more conducive to improving the composite pipe molding performance.


Subject(s)
Surgical Instruments , Zea mays , Technology , Soil , Water
12.
World J Surg Oncol ; 22(1): 91, 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38600546

ABSTRACT

OBJECTIVE: To compare the efficacy of ultrasounic-harmonic scalpel and electrocautery in the treatment of axillary lymph nodes during radical surgery for breast cancer. METHODS: A prospective study was conducted in the Department of Breast Surgery, Zhongda Hospital Affiliated to Southeast University. A total of 128 patients with pathologically confirmed breast cancer who were treated by the same surgeon from July 2023 to November 2023 were included in the analysis. All breast operations were performed using electrocautery, and surgical instruments for axillary lymph nodes were divided into ultrasounic-harmonic scalpel group and electrocautery group using a random number table. According to the extent of lymph node surgery, it was divided into four groups: sentinel lymph node biopsy, lymph node at station I, lymph node at station I and II, and lymph node dissection at station I, II and III. Under the premise of controlling variables such as BMI, age and neoadjuvant chemotherapy, the effects of ultrasounic-harmonic scalpel and electrocautery in axillary surgery were compared. RESULTS: Compared with the electrosurgical group, there were no significant differences in lymph node operation time, intraoperative blood loss, postoperative axillary drainage volume, axillary drainage tube indwelling time, postoperative pain score on the day after surgery, and the incidence of postoperative complications (p>0.05). CONCLUSION: There is no significant difference between ultrasounic-harmonic scalpel and electrocautery in axillary lymph node treatment for breast cancer patients, which can provide a basis for the selection of surgical energy instruments.


Subject(s)
Breast Neoplasms , Humans , Female , Breast Neoplasms/surgery , Breast Neoplasms/pathology , Prospective Studies , Lymph Node Excision , Sentinel Lymph Node Biopsy , Surgical Instruments , Electrocoagulation/adverse effects , Lymph Nodes/surgery , Lymph Nodes/pathology , Axilla/pathology
14.
BMC Surg ; 24(1): 110, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622597

ABSTRACT

BACKGROUND: The reporting of surgical instrument errors historically relies on cumbersome, non-automated, human-dependent, data entry into a computer database that is not integrated into the electronic medical record. The limitations of these reporting systems make it difficult to accurately estimate the negative impact of surgical instrument errors on operating room efficiencies. We set out to determine the impact of surgical instrument errors on a two-hospital healthcare campus using independent observers trained in the identification of Surgical Instrument Errors. METHODS: This study was conducted in the 7 pediatric ORs at an academic healthcare campus. Direct observations were conducted over the summer of 2021 in the 7 pediatric ORs by 24 trained student observers during elective OR days. Surgical service line, error type, case type (inpatient or outpatient), and associated length of delay were recorded. RESULTS: There were 236 observed errors affecting 147 individual surgical cases. The three most common errors were Missing+ (n = 160), Broken/poorly functioning instruments (n = 44), and Tray+ (n = 13). Errors arising from failures in visualization (i.e. inspection, identification, function) accounted for 88.6% of all errors (Missing+/Broken/Bioburden). Significantly more inpatient cases (42.73%) had errors than outpatient cases (22.32%) (p = 0.0129). For cases in which data was collected on whether an error caused a delay (103), over 50% of both IP and OP cases experienced a delay. The average length of delays per case was 10.16 min. The annual lost charges in dollars for surgical instrument associated delays in chargeable minutes was estimated to be between $6,751,058.06 and $9,421,590.11. CONCLUSIONS: These data indicate that elimination of surgical instrument errors should be a major target of waste reduction. Most observed errors (88.6%) have to do with failures in the visualization required to identify, determine functionality, detect the presence of bioburden, and assemble instruments into the correct trays. To reduce these errors and associated waste, technological advances in instrument identification, inspection, and assembly will need to be made and applied to the process of sterile processing.


Subject(s)
Operating Rooms , Surgical Instruments , Humans , Child , Hospitals
20.
Turk Neurosurg ; 34(3): 377-387, 2024.
Article in English | MEDLINE | ID: mdl-38650551

ABSTRACT

AIM: To compare endovascular coiling and surgical clipping for the evaluation of clinical outcomes in patients with unruptured intracranial aneurysms. MATERIAL AND METHODS: We searched MEDLINE, EMBASE, the Cochrane Library and three Chinese domestic electronic databases, namely, Wanfang, CNKI and VIP for studies published between January 1990 and January 2018. We included controlled clinical studies comparing clinical outcomes between surgical clipping and endovascular coiling treatments. Two researchers extracted the data and assessed the quality of the studies, and a meta-analysis was performed using RevMan 5 software. RESULTS: We analysed a total of 23 controlled clinical studies including 117,796 cases. Meta-analysis demonstrated similar ischaemia rates between clipping and coiling with an odds ratio [OR] of 1.36 (95% CI: 0.77?2.40). The occlusion rate and bleeding risk were higher with clipping than coiling; the pooled ORs were 5.31 (95% CI: 3.07?9.19) and 2.39 (95% CI: 1.82?3.13), respectively. In addition, clipping resulted in a longer hospital stay (OR = 2.90, 95% CI: 2.14?3.65) than coiling did. Patients who underwent clipping had a higher short-term mortality (OR = 1.99, 95% CI: 1.70?2.33) and neurological deficit rate (OR = 2.05, 95% CI: 1.73? 2.44) compared with those who underwent coiling. However, 1 year mortality and deficit rate were similar for both clipping and coiling, with pooled ORs of 0.75 (95% CI: 0.41?1.38) and 0.94 (95% CI: 0.53?1.67), respectively. Funnel plots did not demonstrate a publication bias, with the exception of ischaemic outcome, and sensitivity analysis showed consistent results. CONCLUSION: Our study demonstrates that coiling is associated with a lower rate of occlusion, shorter hospital stay, lower bleeding risk and lower short-term mortality and morbidity compared with clipping. In terms of ischaemic risk, 1 year mortality and morbidity, coiling and clipping bear a similar risk. In addition, we speculate that surgical clipping may have a better outcome than endovascular coiling in the long term especially in young patients. Further research is needed to confirm our conclusion.


Subject(s)
Endovascular Procedures , Intracranial Aneurysm , Surgical Instruments , Humans , Intracranial Aneurysm/surgery , Intracranial Aneurysm/therapy , Endovascular Procedures/methods , Treatment Outcome , Neurosurgical Procedures/methods , Embolization, Therapeutic/methods , Embolization, Therapeutic/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...